Yazar "Demircan, Sabri" için listeleme
-
Comparison of long-term follow-up in patients with single or dual chamber pacemakers: is downtrodden or take its rightful place?
Usalp, Songul; Demircan, Sabri; Yildiz, Omer; Baskurt, Murat; Kaplan, Ozgur; Canbolat, Ismail; Yazicioglu, Nuran (Edizioni Minerva Medica, 2019)BACKGROUND: in this study, at a median follow-up of 7.9 years (3-22), the patients who had implanted either single chamber (VDD) or dual chamber (DDD) pacemakers were compared according to the changes in left ventricular ... -
The effect of different treatment strategies on left ventricular myocardial deformation parameters in patients with chronic renal failure
Yildirim, Ufuk; Gulel, Okan; Eksi, Alay; Dilek, Melda; Demircan, Sabri; Sahin, Mahmut (SPRINGER, 2018)The aim of this study was to compare left ventricular (LV) functions by speckle tracking echocardiography (STE) in chronic kidney disease (CKD) patients in various stages and under different renal replacement treatments ... -
IMPACT OF PRE-STENT IMPLANTATION PLAQUE BURDEN ON THE DEVELOPMENT OF STENT RESTENOSIS
Yanik, Ahmet; Kaplan, Ozgur; Aksan, Gokhan; Dagasan, Goksel; Sunter, Ahmet Tevfik; Yuksel, Serkan; Demircan, Sabri (DERMAN MEDICAL PUBL, 2017)Aim: In this study we have used quantitative coronary angiography (QCA) and the Image J program in order to investigate the influence of plaque area, as identified prior to stent implantation, on the development of stent ... -
Relation of the aortic stiffness with the GRACE risk score in patients with the non ST-segment elevation myocardial infarction.
Gedikli, Ömer; Aksan, Gökhan; Uzun, Adem; Demircan, Sabri; Soylu, Korhan (e-Century Publishing Corporation, 2014)BACKGROUND: Current guidelines recommend clinical risk scoring systems for the patients diagnosed and determinated treatment strategy with in Non-ST-elevation elevation myocardial infarction (NSTEMI). Previous studies ... -
Report of a Case of Pacemaker Depletion Presenting with Wide QRS Tachycardia
Kaplan, Ozgur; Aydin, Ertan; Demircan, Sabri (AVES, 2017)Runaway pacemaker results from pacemaker malfunction and is characterized by sudden increases in the stimulus rate above the set upper rate limit of the pacemaker. Here we report the case of a patient with wide QRS complex ... -
Treatment of ineffective endocardial defibrillation with subcutaneous array: a case report
Kaplan, Ozgur; Demircan, Sabri (TURKISH SOC CARDIOLOGY, 2017)Defibrillation threshold (DFT) testing is an important part of ICD implantation. After placement of the ICD generator, a DFT test is performed to evaluate the integrity of the ICD system and to confirm a successful ... -
VDD ve DDD pacemaker implante edilen hastaların uzun dönem sol ventrikül sistolojik fonksiyonlarının ekokardiyografik ve elektrokardiyografik parametrelerinin karşılaştırılması
Usalp, Songül (İstanbul Bilim Üniversitesi, Tıp Fakültesi, 2015)Amaç: VDD pacemaker sistemi, atriyoventriküler blok varlığında atriyal sensing yapıp ventrikülü uyararak atriyoventriküler senkron çalışmayı sağlayan, tek lead ve bataryadan ibaret pacemaker sistemidir. DDD pacemaker sistemi ...