Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorRaziye Gün Dönmez
dc.contributor.authorAlev Koçkar
dc.contributor.authorNadir Koçkar
dc.date.accessioned2019-08-13T12:10:23Z
dc.date.accessioned2019-08-13T15:50:00Z
dc.date.available2019-08-13T12:10:23Z
dc.date.available2019-08-13T15:50:00Z
dc.date.issued2016
dc.identifier.issn1305-9173
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TWpFNE1qZ3hNUT09
dc.identifier.urihttp://hdl.handle.net/11446/1589
dc.description.abstractAmaç: Santral kornea kalınlığının (SKK) diürnal ritim üzerine olan etkisinin değerlendirilmesi. Gereç ve Yöntem: Hakkari Devlet Hastanesi Göz Hastalıkları Polikliniği'nde Mayıs 2012-Eylül 2013 tarihleri arasında aynı hekim tarafından değerlendirilen ve ölçümleri yapılan 52 hastanın 104 gözüne ait sonuçlar geriye dönük olarak incelendi. SKK'ya göre >520 µm ve <=520 µm olanlar; Göz içi basıncı (GİB) dalgalanması >=5 mmHg ve <5 mmHg olanlar gruplara ayrıldı. Bulgular: Toplam 52 hastanın 30'u (%58) erkek, 22'si (% 42) kadındı. SKK <=520 µm olan olguların ortalama GİB düzeyleri tüm ölçüm saatlerinde anlamlı olarak düşük bulundu (p<0,01). Olguların ortalama GİB değerlerinde sabah saatlerine göre öğleden sonra anlamlı olarak düşme saptandı (p<0.05). SKK >520 µm olan olgularda >=5 mmHg GİB dalgalanmasının anlamlı olarak daha fazla olduğu saptandı (p<0.05). Sonuç: SKK yüksek olan olgularda GİB dalgalanması yanıltıcı olabilir, hastanın glokom riski oluşturabilecek diğer parametreler açısından dikkatli tetkiki gerekir.en_US
dc.description.abstractPurpose: To evaluate the effect of central corneal thickness (CCT) on diurnal variation of intraocular pressure (IOP). Materials and Methods: This retrospective study involved an evaluation of eyes of 52 patients, a total of 104 eyes, who were followed-up and measured their IOP by the same physician between May 2012 and September 2013 in the eye clinic of Hakkari State Hospital. Patients were grouped by their CCT (&gt;520 &micro;m and &lt;=520 &micro;m) and diurnal IOP variation (&gt;=5 mmHg and &lt;5 mmHg). Results: Of the 58% of patients (n=30) were male, and 42% (n=22) of them were female. Intraocular pressure (IOP) of the subjects who had CCT &lt;=520 &micro;m were found significantly lower at all measurements (p&lt;0.01). It was found that mean IOP of the subjects were lower in the afternoon hours than in the morning (p&lt;0.05). Subjects who had CCT &gt;520 &micro;m had significantly more &gt;=5 mmHg IOP fluctuation (p&lt;0.05) . Conclusion: IOP fluctuation may cause false results in patients with high CCT. Therefore, patients need to be evaluated carefully in terms of other parameters which cause risk for glaucoma.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGöz Hastalıklarıen_US
dc.titleSantral Kornea Kalınlığının Diürnal Ritim Üzerine Olan Etkisien_US
dc.title.alternativeTo Evaluate the Effect of Central Corneal Thickness on Diurnal Variation of Intraocular Pressureen_US
dc.typearticleen_US
dc.relation.journalGlokom Katarakten_US
dc.departmentDBÜen_US
dc.identifier.issue4en_US
dc.identifier.volume11en_US
dc.identifier.startpage249en_US
dc.identifier.endpage252en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster