dc.contributor.author | Tekin I. | |
dc.contributor.author | Demir M. | |
dc.contributor.author | Özdem S. | |
dc.date.accessioned | 2024-02-04T13:30:14Z | |
dc.date.available | 2024-02-04T13:30:14Z | |
dc.date.issued | 2022 | |
dc.identifier.issn | 17498090 | |
dc.identifier.uri | https://doi.org/10.1186/s13019-022-01752-7 | |
dc.identifier.uri | http://hdl.handle.net/11446/4875 | |
dc.description.abstract | Background: Ischemia–reperfusion injury of saphenous vein grafts (SVG) during coronary artery bypass grafting surgery negatively impacts endothelial integrity and functionality and is associated with vein graft failure. The aim of this study was to evaluate the level of oxidative stress in human SVG segments following ischemic storage in three intraoperative graft storage solutions: saline (S), autologous heparinized blood (HB) and DuraGraft (DG). Methods: 3 mm tissue rings derived from surplus SVG segments from 50 patients were stored at room temperature for 30 min in DG, S or HB. Total oxidative status (TOS) and total antioxidant status (TAS) levels were determined from which the oxidative stress index (OSI: TOS/TAS ratio) was calculated. A p-value < 0.017 was considered significant implementing a Bonferroni correction. Results: TOS values were significantly lower for DG stored samples in comparison to both S and HB; there was no difference between S and HB (DG: 32.6 ± 1.8, S: 39.6 ± 2.8 and HB: 40.6 ± 2.4 µmol H2O2 eqv.; DG vs. S and DG vs. HB p < 0.0001, S vs. HB p = 0.047). TAS was higher for both DG and HB in comparison to S (DG: 8.9 ± 0.9, S: 6.9 ± 1.0 and HB: 8.6 ± 0.9 mmol Trolox eqv.; DG vs S p < 0.0001, DG vs. HB p = 0.263, S vs. HB p < 0.0001). OSI differed between all groups with the lowest value for DG (DG: 3.7 ± 0.2, S: 5.8 ± 0.4 and HB: 4.7 ± 0.2 µmol H2O2 eqv./mmol Trolox eqv.; all p < 0.0001). Conclusions: Saphenous veins grafts stored in DuraGraft had a lower oxidative level, higher antioxidant level and a lower oxidative stress index in comparison to saphenous vein grafts stored in saline or heparinized blood. ClinicalTrials.gov Identifier NCT02922088. © 2022, The Author(s). | en_US |
dc.description.sponsorship | Illinois Department of Public Health, IDPH; Akdeniz Üniversitesi | en_US |
dc.description.sponsorship | Mestan Emek, Department of Public Health, Akdeniz University Faculty of Medicine, Antalya, Turkey performed the statistical analysis. Marizyme prepared the figure. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | BioMed Central Ltd | en_US |
dc.relation.ispartof | Journal of Cardiothoracic Surgery | en_US |
dc.identifier.doi | 10.1186/s13019-022-01752-7 | |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Coronary artery bypass graft | en_US |
dc.subject | Endothelial damage inhibitor | en_US |
dc.subject | Storage solution | en_US |
dc.subject | Vein graft failure | en_US |
dc.subject | hydrogen peroxide | en_US |
dc.subject | coronary artery bypass graft | en_US |
dc.subject | human | en_US |
dc.subject | oxidative stress | en_US |
dc.subject | saphenous vein | en_US |
dc.subject | Coronary Artery Bypass | en_US |
dc.subject | Humans | en_US |
dc.subject | Hydrogen Peroxide | en_US |
dc.subject | Oxidative Stress | en_US |
dc.subject | Saphenous Vein | en_US |
dc.title | Effect of different storage solutions on oxidative stress in human saphenous vein grafts | en_US |
dc.type | article | en_US |
dc.department | DBÜ | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.volume | 17 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.department-temp | Tekin, I., Department of Cardiovascular Surgery, Manavgat Government Hospital, Manavgat, Turkey, Department of Cardiovascular Surgery, Faculty of Medicine, Bahçeşehir University, İstanbul, Turkey; Demir, M., Department of Biochemistry, Medicalpark Hospital Complex, Antalya, Turkey, Faculty of Health Science, Bilim University, Antalya, Turkey; Özdem, S., Department of Medical Biochemistry, Faculty of Medicine, Akdeniz University, Antalya, Turkey | en_US |
dc.identifier.pmid | 35034655 | en_US |
dc.identifier.scopus | 2-s2.0-85122923909 | en_US |
dc.authorscopusid | 15844262400 | |
dc.authorscopusid | 56689396100 | |
dc.authorscopusid | 6701608054 | |