This study aimed to test and compare the biomechanical properties of three tibial fixation methods of anterior cruciate ligament (ACL) tendon grafts under cyclic load and load-to-failure testing in the bovine proximal tibiae, comprising (1) staple fixation alone, (2) interference screw fixation alone, and (3) interference screw fixation with a supplementary staple. Twenty-four bovine tibiae used in the study were divided into three groups (eight proximal tibiae in each group) based on tibial fixation methods of ACL tendon grafts: group A (a spiked ligament staple alone), group B (a cannulated interference screw alone), and group C (a cannulated interference screw with a supplementary staple). Each graft fixation was exposed to cyclic loading conditions. Significant differences were determined in failure load among the three groups (p = 0.008). The mean failure load was significantly higher in group B (717.04 +/- 218.51 N) than in group A (308.03 +/- 17.22 N) (p = 0.006). No significant differences were observed among the groups regarding axial stiffness (p = 0.442). Cyclic displacement differed significantly among the three groups (p = 0.005). In pairwise comparisons, the mean cyclic displacement was significantly higher in group A (8.22 +/- 3.24 mm) compared with group C (1.49 +/- 0.41 mm) (p = 0.005). Failure displacement varied considerably among the groups (p = 0.037). Although group B (15.53 +/- 6.43 mm) exhibited a greater mean failure displacement than both group A (4.9 +/- 0.75 mm) and group C (8.84 +/- 4.65 mm), these differences did not reach statistical significance (p = 0.602 and p = 0.329, respectively). Interference screw fixation alone and supplementary staple fixation have biomechanically similar characteristics in terms of initial strength and stiffness of tibial ACL soft tissue graft fixation. Regardless of staple use, an interference screw with the same diameter as the tibial tunnel can ensure sufficient tensile strength in tibial ACL graft fixation.
Volume
37Issue
10Collections
Related items
Showing items related by title, author, creator and subject.
-
The Effect of Supplementary Staple Fixation on Biomechanical Properties of Soft Tissue Graft Tibial Fixation in Anterior Cruciate Ligament Reconstruction
Ylldlrlm, C.; Demirel, M.; Koraman, E.; Murato?lu, O.G.; Yamak, F.; Bozda?, S.E.; Kocabey, Y. (Georg Thieme Verlag, 2023)This study aimed to test and compare the biomechanical properties of three tibial fixation methods of anterior cruciate ligament (ACL) tendon grafts under cyclic load and load-to-failure testing in the bovine proximal ... -
Simultaneous repair of chronic full-thickness rotator cuff tears during fixation of proximal humerus fractures and clinical results.
Aksu, Neslihan; Aslan, Ömer; Kara, Ayhan Nedim; Işıklar, Zekeriya Uğur (Ekin Medical Publishing, 2010)OBJECTIVES: We investigated the incidence of chronic rotator cuff tears encountered during fixation of proximal humerus fractures with locking plate-screw systems, and evaluated the functional results of simultaneous ... -
A NOVEL LOOP KNOT FOR FIXATION OF RUNNING SUTURES DURING ROBOTIC SURGERY
Kural, Ali Riza; Atug, Fatih; Tufek, Ilter; Akpinar, Haluk (MARY ANN LIEBERT INC, 2011)…