Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDemirhan, Özkan
dc.contributor.authorKasapoğlu, Tugçe
dc.contributor.authorEce, Ferah
dc.contributor.authorToker, Alper
dc.date.accessioned2015-09-17T10:49:13Z
dc.date.available2015-09-17T10:49:13Z
dc.date.issued2013
dc.identifier.citationDemirhan O, Kasapoglu T, Ece F, Toker A. The use of Jackson-Pratt silicone flat drains as prolonged pleural catheters for the management of pleural effusions. J Thorac Dis. 2013; 5(3): 265-269. Demirhan O, Kasapoglu T, Ece F, Toker A. The use of Jackson-Pratt silicone flat drains as prolonged pleural catheters for the management of pleural effusions. J Thorac Dis. 2013; 5(3): 265-269. doi: 10.3978/j.issn.2072-1439.2013.06.15.en_US
dc.identifier.issn2072-1439
dc.identifier.urihttp://www.jthoracdis.com/en_US
dc.identifier.urihttps://hdl.handle.net/11446/796en_US
dc.descriptionİstanbul Bilim Üniversitesi, Tıp Fakültesi.en_US
dc.description.abstractIntroduction: Imbalance between secretion and absorbtion of pleural fluid results in pleural effusion. Emergence of pleural effusion ipsilateral or contralateral to the side drained previously is named recurrent effusion. There is currently no standart approach for the management of recurrent pleural effusions. Materials and methods: Eighteen patients, treated between 2011 and 2012 for recurrent pleural effusions due to various etiologies, not considered for surgical or other treatments, and underwent placement of prolonged pleural catheters ( Jackson-Pratt drain ) were included in this study. Twenty two prolonged pleural catheters were inserted in 18 patients. There were 10 females and 8 males, with mean age 59 (35-77). In 20 patients the catheters were inserted by an anterior approach, and by a posterior approach in one patient. Daily drainage above 1,500 mL was not permitted in order to avoid pulmonary edema. Catheters were removed in patients who had lung expansion and drainage under 50 mL/day.en_US
dc.language.isoengen_US
dc.publisherPioneer Bioscience Pub. Co.en_US
dc.identifier.doi10.3978/j.issn.2072-1439.2013.06.15en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectpleural effusionen_US
dc.subjectprolonged pleural catheteren_US
dc.subjectpleurodesisen_US
dc.titleThe use of Jackson-Pratt silicone flat drains as prolonged pleural catheters for the management of pleural effusionsen_US
dc.typearticleen_US
dc.relation.journalJournal of thoracic diseaseen_US
dc.departmentDBÜ, Tıp Fakültesien_US
dc.identifier.issue3
dc.identifier.volume5
dc.identifier.startpage265
dc.identifier.endpage269en_US
dc.contributor.authorIDTR40362en_US
dc.contributor.authorIDTR143777en_US
dc.contributor.authorIDTR141051en_US
dc.contributor.authorIDTR175564en_US
dc.relation.publicationcategoryBelirsizen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster